AT528 Handheld AC milliohm meter
ACTIVE
USB-232
SCPI
DATA LOGGERUSB-DISK
OVERVIEW
    AT528 handheld battery tester is an instrument can test both battery internal resistance and voltage simultaneously, adopting high performance

    32 bit ARM micro processor control, with full real time inspection.##(Built-in high capacity Lithium battery to realize super long standby time. AT528 has characteristics of both portability of handheld meter and superior perfrmance of benchtop instrument, with performance compatible with Hioki3554, capable of testing0.01mΩ~2.000kΩ resistance, 0-50V DC voltage. It can display 2200 digits of resistance ,5000 digits of voltage. When measure speed is below 10 t/s, 0.5% accuracy can still be attained, with reading beat below 3 characters.

    Resistance measuring adopts vector testing principle, and voltage measuring adopts differential test principle,leading to accurat test open circuit. In addition, this instrument has special sorting function, built-in sorting recording. With OK/NG sorting results displaying sorting beep setting, this instrument can be used for automatic sorting system fulfilling full automatic assembly line test. AT528 is equipped with 500 groups of data storage capable of saving tested data by one key touch, saving your data restoring time. Moreover, it has USB interface for remote control and data collecting any analysis, making it suitable for assembly line inspection of various kinds of battery.
FEATURES
  • Fresh and dazzling two-color casting shell
  • Battery and external power supply mode
  • Four-terminal test
  • Switch between Chinese and English
  • Backlight adjustment
  • Auto power off setting
  • Power consumption≤5W
  • Super long continuous working time ≥ 8h
SPECIFICATIONS
ParametersACR, DCV
AccuracyR: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
RangeR: 0.01mΩ~2.000kΩ V:1mV~50V
Signal SourceAC:1kHz open circuit voltage:<30mV Test current:<15mA
Range6 ranges, automatic, manual, nominal
Speed20 times/s, 10 times/s, 3 times/s
Result DisplayABS/PER/SEQ
Display MaxR:2200 V:5000
AdjustmentShort-circuit Correction
Comparatorresistance & voltage compare separately, voltage & resistance combine compare, GD/NG sorting display, beep
TriggerInternal, Manual, Remote
InterfaceBuild-in Mini-USB, charging interface, U-disc interface
OptionsATL506B
PowerV:100-240V~50/60Hz 0.35A output:9V 1A DC ##8.4V 2200mAh Li battery
Dimensions130.23 x210.76x37.88 mm
Mass650g
AccessoriesATL501B 4 terminal fixture ATL909 DC adaptor ATL202 bag ATL804 Li battery ATL105Mini-USB communication cable
Other functions3.5 inch 16M color TFT-LCD display, keypad lock, data hold function,compatible SCPI order set; Chinese & English language, adjustable background, auto power-off, 500 groups measured data saved with one key
APPLICATIONS
    IMeasure all kinds of low-voltage batteries, accumulators, lithium batteries, mobile phone batteries
    Contact resistance, battery internal resistance
    battery voltage
DOCUMENTATION
DOCUMENTS
DATASHEET ENGLISH

|

CHINESE
USER'S GUIDE ENGLISH

|

CHINESE
ACCESSORIES
STANDARDS
NONE
OPTIONS
NONE
SOFTWARE
NONE
RELATED PRODUCTS

Compare

AT520L

  • Parameters: AC Resistance , DC voltage
  • Accuracy: R: 0.3%, V: 0.05%
  • Range: R: 1μΩ- 3.2kΩ, V:100μV-60V DC
  • Signal Source: AC 1kHz, open-circuit voltage smaller than 20mV, measurement current smaller than 10mA
  • Range: Automatic and manual with 6 ranges

Compare

AT525

  • Parameters: ACR DCV
  • Accuracy: R:0.5%±5dgt(resolution 0.001mΩ)V:0.05%±5dgt(resolution 0.1mV)
  • Range: R:0.001mΩ~3.3000Ω V:0.0001V~60.000V
  • Signal Source: AC:1kHz open-circuit voltage:<30mV Test current:<15mA
  • Range: Automatic, Manual, Norminal, 4 ranges

Compare

AT526

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT526B

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ ~ 33.00Ω V:0.0001V~60.000VDC
  • Signal Source: AC 1kHz,open circuit voltage <20mV,Test current:<150mA
  • Range: Automatic & Manual , 5 ranges

Compare

AT526C

  • Parameters: AC Resistance, DC voltage
  • Accuracy: Resistance:0.5% ; Voltage:0.01%
  • Range: Resistance:0.001mΩ~33.000kΩ Voltage:0.00001V~120.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: 7 ranges, auto & manual

Compare

AT527

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~3.3000kΩ & 0.00001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges,3mΩ~3kΩ. auto , manual,, nominal.

Compare

AT527A

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT527B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1000.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT527L

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3.3kΩ & 0.00001~60.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~30Ω with 7 ranges. automatic, manual and nominal.

Compare

AT528L

  • Parameters: ACR, DCV
  • Accuracy: R: 0.5%±5dgt(resolution:0.01mΩ) V:0.1%±5dgt(resolution:1mV)
  • Range: R: 0.01mΩ~2.000kΩ V:1mV~50V
  • Signal Source: AC:1kHz open circuit voltage:<30mV Test current:<15mA
  • Range: 4 ranges, automatic, manual, nominal

Compare

AT526G

  • Parameters: ACR, DCV
  • Accuracy: R:0.5% V:0.01%
  • Range: R:0.001mΩ~33.000kΩ V:0.00001V~400.000VDC
  • Signal Source: AC 1kHz,Test current:<150mA
  • Range: Automatic & Manual, 7 ranges

Compare

AT527F

  • Parameters: ACR, DCV
  • Accuracy: Resistance accuracy: 0.5%,Voltage accuracy: 0.01%
  • Range: Test range:0.0001mΩ~3kΩ & 0.00001~200.000V
  • Signal Source: 1kHz, stable frequency: 20ppm
  • Range: 3mΩ~3kΩ with 7 range test.Auto, manual, Nominal.

Compare

AT572B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance 0.5%,voltage accuracy 0.01%
  • Range: Test range 0.0001mΩ~3kΩ & 0.00001~800.000V
  • Signal Source: 1kHz, Frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. Automatic,Manual and Nominal

Compare

AT527K

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of resistance: 0.5%,voltage: 0.01%
  • Range: Test range: 0.0001mΩ~3kΩ & 0.00001~1500.00V
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 3mΩ~3kΩ with 7 ranges. automatic, manual and nominal.

Compare

AT529

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~400.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529A

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~200.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529B

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~800.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.

Compare

AT529H

  • Parameters: ACR, DCV
  • Accuracy: Accuracy of Resistance 0.5%, voltage 0.01%
  • Range: Test range 0.0001mΩ~330000Ω & 0.000001V~1000.000VDC
  • Signal Source: 1kHz, frequency stability: 20ppm
  • Range: 7 ranges automatic, manual, and nominal. Range nominal: The instrument will automatically select the range based on the nominal value.
Privacy | Term of Use | Help
©2024-2024 Onmeas Ltd. 苏ICP备2024084829号